Asynchronous Terminals and Printer Processes Programming Manual
 3681 MULTIFUNCTION CONTROLLER
 Console Messages for the 3681
 | CONSOLE MESSAGES FOR THE 3681
 |
 |
 | Console messages posted by CSM cannot be logged for the 3681
 | implementation because CSM is not defined for the 3681 implemen-
 | tation of ATP6100. In addition, console messages related to
 | the download operation are not logged for 3681. However, the
 | following console messages will continue to be logged for 3681:
 |
 | 04 device error
 | 06 line or device UP message
 | 07 line or device DOWN message
 | 74 process internal error
 | 165 CSS subdevice error
 |
 |
 |
 | CMI LIMITATIONS FOR THE 3681
 |
 |
 | The 3681 implementation allows you to issue most CMI commands.
 | However, there are some limitations associated with the ALTER,
 | CONTROL, INFO, and STATUS commands. In addition, statistical
 | items, as well as the SU object, are affected.
 |
 |
 |
 | ALTER Command Limitation
 |
 |
 | The attributes associated with the LINE object are not alterable
 | using the ALTER command. If you attempt to alter these
 | attributes with the ALTER command, a FEINVALOP (02) message
 | displays indicating the attribute has been rejected.
 |
 |
 |
 | CONTROL Command Limitation
 |
 |
 | The 3681 does not support the CONTROL command because the
 | controller is not downloaded from the NonStop System. If you
 | attempt to issue the CONTROL command, a FEINVALOP (02) message
 | displays. This message indicates the command has been rejected.
 |
 |
 |
 | INFO Command Limitation
 |
 |
 | Line attributes do not apply to the 3681 implementation. The
 | DEBUG, PROGRAM, and PROTOCOLID fields in the INFO display are
 | blank.
 F-4 November 1987