Asynchronous Terminals and Printer Processes Programming Manual
 PRINTER I/O
 Flow Control Characteristics
 Table 5-2. Flow Control Characteristics
 SYSGEN CMI
 Characteristic Modifier Attribute
 _______________________________________________________________
 CTS flow control ** CTSFLOW CTSFLOW
 ETX(ENQ)/ACK flow control ** ETXFLOW ETXFLOW
 NOETXFLOW
 Specify ETX character ** ETXFLOWCHAR ETXFLOWCHAR
 | Delay time *** DELAYTIME DELAYTIME
 Transmit pause TPAUSE TPAUSE
 NOTPAUSE
 Reverse transmit pause * REVTPAUSE REVTPAUSE
 NOREVTPAUSE
 Specify XON character ** XONCHAR XONCHAR
 Specify XOFF character ** XOFFCHAR * XOFFCHAR
 _______________________________________________________________
 * Supported by APT6100 only
 ** For 5540/1 and DTR-type printers only
 | *** For 5540/1, DTR-type, and 5515/5516 printers only
 CTS flow control is available only for ATP6100 subdevices. The
 CTSFLOW SYSGEN modifier turns on CTS flow control. You can
 change the SYSGEN default by including the CTSFLOW attribute in
 the CMI ALTER SU command. When CTS flow control is selected,
 CSSPRINT monitors the CTS signal. When CTS is low, CSSPRINT
 waits to transmit until the signal goes high.
 For ATP6100, the ETXFLOWCHAR SYSGEN modifier allows you to
 specify a character to be used for termination of read opera-
 tions. You can change the SYSGEN default by including the
 ETXFLOWCHAR attribute in a CMI ALTER SU command.
 Transmit pause (TPAUSE) and reverse transmit pause (REVTPAUSE)
 allow a buffered RS-232 subdevice to delay transmission of data
 from the controller so the device can empty its buffer. For
 TPAUSE, the device must raise its secondary received line signal
 5-6 November 1987