ATM Configuration and Management Manual

SCF Commands
ATM Configuration and Management Manual522307-003
4-75
STATS PROCESS Command
Command Syntax
OUT file-spec
causes any SCF output generated for this command to be directed to the specified
file.
PROCESS process-name
specifies the name of the PROCESS for which statistics are to be displayed.
RESET
specifies the statistical counters are to be reset.
STATS PROCESS Display
The format of the display for the STATS PROCESS command is:
Sample Time
specifies the time the statistics sample was taken.
Reset Time
specifies the time the statistics counters were last reset.
Configured Interval
specifies the configured probe interval. The probe interval is specified in 1/100 of a
second.
STATS [/OUT <file-spec>/] PROCESS process-name [ , RESET ]
-> STATS PROCESS $ZAM1
ATM Stats PROCESS \HANSOLO.$ZAM1
Sample Time.............. 10 Feb 1998, 13:26:17.615
Reset Time............... 10 Feb 1998, 11:31:36.617
SNet Path/Probe Related
Configured Interval...... 300 Configured Count......... 3
No. Times Inaccessible... 0D
Probes Sent.............. 2290D Timeouts................. 0D
Good Responses........... 2290D Send Errors.............. 0D
Consecutive Good Resp.... 2290D Consecutive Errors....... 0D
Highwater Consec Good.... 2290D Highwater Consec Errors.. 0D
Highwater Resp (msec).... 103401D
Last Time Inaccessible... 10 Feb 1998, 11:31:36.681
Shared Memory Related
Nsk Events................ 4324D Nsk Event Errors........ 0D
Get Md Attempts........... 4363D Get Md Errors........... 0D
Return Md Attempts........ 4540D Return Md Errors........ 0D