ATM Configuration and Management Manual

ATM Event Messages
ATM Configuration and Management Manual522307-003
B-27
609
symptom string
specifies where in the software the error was detected.
reporting method
specifies where in the software the error was generated.
Cause. The AMP read the power on self-test results from the adapter which indicated
the tests detected an error.
Effect. The adapter cannot be started.
Recovery. If an SCF command was issued, retry the command. If the problem
persists, replace the adapter or update the firmware.
609
subject
specifies the subject for the event as Atm-Adapter.
severity
specifies the severity of the event as Critical.
secondary subject
specifies the secondary subject for the event as Amp-Process.
group
specifies the physical group location of the adapter.
module
specifies the physical module location of the adapter.
slot
specifies the physical slot location of the adapter.
major
specifies the adapter defined major error code.
00000 ATM: Adapter Software Failure subject,
Severity: severity [, secondary subject],
Adapter Location: (GRP group, MOD module, SLOT slot)
[Major: major, Minor: minor, Info: info, PC: Oxpc,
Version: version string, Error: error string,
File: file name.#line number]
[, Reporting Method: reporting method]