ATM Configuration and Management Manual
ATM Event Messages
ATM Configuration and Management Manual—522307-003
B-29
700
secondary subject
specifies the secondary subject for the event as Amp-Process.
group
specifies the physical group location of the adapter.
module
specifies the physical module location of the adapter.
slot
specifies the physical slot location of the adapter.
dump file name
specifies the dump file.
oxblock address
specifies the address of the dump block.
block size
specifies the size of the dump block.
symptom string
specifies where in the software the error was detected.
reporting method
specifies where in the software the error was generated.
Cause. Specifies the AMP detected a checksum error on a received dump block from
the adapter.
Effect. The block is written to the dumpfile with all
FF
s as the data for the block.
Recovery. None. This is an informational event.
700
subject
specifies the subject for the event as ATM-Line.
00700 Object Available subject, Event Number: event,
Reason: reason, Previous State: state, Current State: state,
[, Manager: manager name ] [, Batch ID: jobid ]
[, User Content: text ]