ATM Configuration and Management Manual
SCF Commands
ATM Configuration and Management Manual—522307-003
4-30
ADD ADAPTER Command
AUTORELOAD { ON | OFF }
specifies if the ADAPTER is automatically reloaded following an ADAPTER reset.
An ON value indicates the ADAPTER software is automatically reloaded.
Default: ON.
PROBEINTERVAL milliseconds
specifies the time interval in 1/100th of a second in which the AMP will send a
probe message to the ADAPTER to verify the adapter path and to verify the
adapter is operational.
Default: 3 seconds.
PROBECOUNT digit
specifies the number of consecutive errors to be detected by the AMP before
declaring the path to the ADAPTER as being inaccessible.
Default: 3.
SYSCONTACT string
specifies the contact person for this managed node. The string specified must be in
the range 0 through 256. This attribute is for informational purposes only.
Default: blanks.
SYSDESC string
specifies the full name and version ID of the system hardware and software,
operating system, and networking components. The string specified must be in the
range 0 through 256. This attribute is for informational purposes only.
Default: blanks.
SYSLOCATION string
specifies the physical location of the device. The string specified must be in the
range 0 through 256. This attribute is for informational purposes only.
Default: blanks.
SYSNAME string
specifies the system name. The string specified must be in the range 0 through
256. This attribute is for informational purposes only.
Default: blanks.