ATM Configuration and Management Manual

SCF Commands
ATM Configuration and Management Manual522307-003
4-39
ALTER LINE Command
MAXVPCS digit
specifies the maximum number of VP connections. The value specified must be in
the range 0 through 256.
Default: 100.
MAXVCCS digit
specifies the maximum number of VC connections. The value specified must be in
the range 0 through 3072.
Default: 100.
MAXVPIBITS digit
specifies the address width and the maximum number of VPI bits that can be
active for this interface. The value specified must be in the range 0 through 8.
Default: 8.
MAXVCIBITS digit
specifies the address width and the maximum number of VCI bits that can be
active for this interface. The value specified must be in the range 0 through 16.
Default: 10.
UMECOMMUNITY community-name
specifies the UNI community name for the management entity. The community
name is specified as a text string enclosed in parenthesis. The length specified
must be in the range 0 through 255.
Default: .
UMEVPI digit
specifies the UME VPI. The value specified must be in the range 0 through 255.
Default: 1.
UMEVCI digit
specifies the UME virtual circuit identifier. The value specified must be in the range
0 through 3017.
Default: 16.
UNIPORTTYPE {public|private}
specifies the public or private ATM UNI type. The value specified must be public or
private.
Default: PUBLIC.