ATM Transaction Anayzer User and Installation Guide
Troubleshooting HP NonStop ATM Transaction Analyzer 138
2. To delete nodes
a. While using SQL authentication
nodemgt.exe -deletenode –node=”\NODE1” –server=(local) –db=ATMTA -sqlauth
–username=sa –password=*****
b. While using Windows authentication
nodemgt.exe -deletenode –node=”\NODE1” –server=(local) –db=ATMTA”
3. To modify nodes:
a. While using SQL authentication
nodemgt.exe -modifynode –node=”\NODE1” –newIP=“111.111.111.111” –
newPort=”6666” –server=(local) –db=ATMTA -sqlauth –username=sa –
password=*****
b. While using Windows authentication
nodemgt.exe - modifynode –node=”\NODE1” –server=(local) –db=ATMTA
7-8 ATM/TA Maintenance Procedure
Follow the steps listed below for changing the Node, IP address and port number for ATM/TA.
1. Stop ATM/TA on the front-end and on the HP NonStop Server.
2. Modify the ELKCONF configuration file using appropriate TCP/IP Stack process name and/or port number.
3. On Application Server, run the Node Management utility that will update the elink.cfg and the ATM/TA
database.
4. Restart ATM/TA, both at the front-end and at the backend.