AutoSYNC Software User's Guide (Update 14)
Installation
HP AutoSYNC User’s Guide—522580-015
2-8
Update the System Coldload and Shutdown
Procedures
If system security is set such that the Authorizer cannot log down to another user ID, 
the following options are available:
1. Configure all scheduled synchronizations with the same user id as the AutoSYNC 
Authorizer. All other users must request one-time synchronizations.
2. Configure multiple AutoSYNC environments, each with its own MAPDB and 
monitor process. Configure each environment to have a different Authorizer, either 
by starting the monitor process with a different user ID or by using the 
AUTHORIZE command. Then, each user can use the AutoSYNC environment 
which corresponds to that user ID.
3. Enable AutoSYNC to operate in a privileged mode. This is the simplest method, 
but requires a privileged ASYSYNCP object file. To use this method, follow the 
instructions described below in Privileged ASYSYNC/ASYSYNCP.
Privileged ASYSYNC/ASYSYNCP
Two circumstances may require the use of a privileged ASYSYNC or ASYSYNCP 
process: 
•
If, on the local system, the AutoSYNC Authorizer does not have the privileges to 
perform a log down to another user ID, one of the options is to license the local 
ASYSYNCP process. See Bypassing Disabled Log Down on page 4-7 for details.
•
For the synchronization of file sets that contain object files with license or progid 
attributes, ASYSYNC (or ASYSYNCP if synchronizing over TCP/IP) on the remote 
system must operate under a local user ID. A local user ID is required to perform 
both scheduled and one-time synchronizations. See Preserving Security Attributes 
on Remote Destinations on page 3-17 for details.
Update the System Coldload and Shutdown Procedures
The monitor process is started after TMF has been started and before any file 
synchronization is attempted. It is advisable to incorporate the restart of the monitor 
process with the other operational steps that normally follow a system cold load. The 
monitor is started by the START MONITOR
 command. The user ID that starts the 
monitor process must have read access to the SysDB and MapDB tables. The user ID 
that starts the monitor process may also be the AutoSYNC authorizer; consult The 
AutoSYNC Authorizer on page 4-1. If the syncusers were suspended prior to shutting 
down AutoSYNC, as recommended below in Shutting Down AutoSYNC
, you will need 
to add a step to activate the syncusers using the ACTIVATE SYNCUSER command.
Update the shutdown procedures to include the shut down steps described below in 
Shutting Down AutoSYNC
.
Install the AutoSYNC EMS templates
The AutoSYNC EMS templates are in the file ZASYTMPL. Please refer to the HP EMS 
template installation instructions to perform this step.