ALTER SYNCFILESET
the start time of a synchronization window or a once-a-day synchronization. 
The time is entered in the format hour:minute:seconds between 00:00:00 and 
23:59:59. The maximum window is 24 hours.
When only the START option is specified the INTERVAL is ignored and one 
synchronization per day is performed at the start time.
If the start time is later than the stop time, then it is assumed the 
synchronization window crosses into the next day.
STOP hh:mm:ss | NO STOP
the ending time of the synchronization window. The time is entered in the 
format hour:minute:seconds between 00:00:00 and 23:59:59. The maximum 
window is 24 hours.
If the stop time is smaller than the start time, then it is assumed the 
synchronization window crosses into the next day.
If STOP is omitted but START is specified, synchronization happens once a 
day at the specified START time.
TIMEEX[ACT] | NO TIMEEX[ACT]
a file is synchronized if the modification timestamp of the source does not 
exactly match the modification timestamp of the destination file.
By default, a file is synchronized only when the source file has been modified 
after the destination file was last modified.
In all cases, the comparison of timestamps accounts for differences in system 
clocks and time zones.
TRIGGER { tacl-command | oss-shell-command } | NO TRIGGER
a TACL command or OSS shell command that is executed by AutoSYNC for 
each file in the synchronized file set after the file has been moved to the 
destination.
The command line contains four built-in arguments. Each argument starts with 
a pound sign (#) and is terminated by a TACL delimiter character such as a 
Note on symbolic links. Because source and destination modification 
timestamps of symbolic links never match, TIMEEXACT is ignored if specified 
for symbolic links. For further details on symbolic link synchronization, see 
paragraph Modification Timestamp of Symbolic Links
 on page 5-4
Note on SQL Shorthand Views.
A SQL view has no modification timestamp. 
Instead AutoSYNC uses creation timestamps. This prevents a shorthand view 
from being synchronized every time the file set is synchronized. 
However if TIMEEXACT is specified, the shorthand view will always be 
synchronized because the creation time of the destination is always newer 
than the creation time of the source. For further details on SQL View 
synchronization, see paragraph SQL Views on page 3-8.