AutoSYNC Software User's Guide (Update 19)
One-time Synchronization
HP AutoSYNC User’s Guide—522580-020
3-8
SQL Views
If the index tables reside in a different subvolume than the base table in the source 
file set, use the MAPNAMES option to specify the mapping of the source names to 
the destination names.
The destination file set must be defined using a filename that has the wild-card 
character asterisk (*); otherwise SQL tries to restore indexes and base table to the 
same filename.  
SQL index tables cannot be synchronized by themselves. AutoSYNC does not 
synchronize an index that is created after the table has been synchronized, unless the 
SQLREDEF option is specified (see Synchronizing based on REDEFINITION 
timestamp below); otherwise, the table must be modified or purged at the destination to 
cause the table and indexes to be resynchronized as a unit.
SQL Views
Protection Views
If you synchronize a SQL table, protection views are implicitly synchronized.
You cannot synchronize a protection view explicitly.
Shorthand Views
A SQL view does not have a modification timestamp. Instead, AutoSYNC compares 
source and destination creation timestamps to determine if the view should be 
synchronized. This prevents the view from being synchronized every time the file set is 
synchronized. 
The creation time of the destination is always different than the creation time of the 
source. Therefore, you should not specify TIMEEXACT on a file set that contains 
shorthand views.
By default, a shorthand view, like a protection view, is synchronized whenever a table it 
references is synchronized, regardless of whether the shorthand view is in the 
syncfileset definition or not.
You can disable the automatic synchronization of shorthand views for a specific 
syncfileset by setting the syncfileset attribute NO SYNCVIEWS.
If automatic shorthand view synchronization is disabled, a shorthand view is not 
automatically synchronized with its referenced tables. When the data in a SQL table 
changes or when the SQL DDL changes and SQLREDEF is configured, Autosync 
synchronizes the table but does not list any associated shorthand view in the BACKUP 
input list, because the view did not change. On the destination, the view is dropped 
when RESTORE drops and replaces the referenced table, but the view is not 
recreated. The view is eventually replaced at the next synchronization.
SYNC $DATA.SQLTBL.MYTBL TO \DEST.$DATA.SQLTBL.MYTBL*;!