AutoSYNC Software User's Guide (Update 20)
Scheduled Synchronization
HP AutoSYNC User’s Guide—522580-021
4-8
Scheduled Synchronization Flow
Scheduled Synchronization Flow
The following paragraphs describe how components of AutoSYNC interact to manage 
and execute scheduled synchronizations:
Monitor Process
ASYSYNCP process
ASYSYNC process
Variant for Synchronization over TCP/IP
Monitor Process
The monitor process accesses the SYNCUSER table to determine the users that have 
been configured by the administrator. Each user has various parameters such as 
maximum priority. A user may be suspended, in which case it is ignored.
For each user ID, uuu,ggg, there should be a file set configuration table named 
SFggguuu. All file sets in these tables are fetched to the monitor’s memory and sorted. 
Suspended file sets are discarded.
The monitor starts a local ASYSYNCP process for each unique combination of user ID, 
known destination system, and batch ID. If a destination system is not available, the 
monitor waits for a system message that declares that the remote system is available, 
and then starts the appropriate processes.
After starting the ASYSYNCP processes, the monitor sends a message to each 
process, containing all file sets that pertain to that process.
The monitor maintains (and checkpoints) a table of ASYSYNCP processes and 
periodically checks that these processes are still alive. If any process fails, or if there 
are network or CPU failures that affect these processes, the monitor takes an 
appropriate corrective action. Simple failures will be retried three times immediately 
and then once every 30 minutes.
If the administrator or a user issues a command that updates the SYNCUSER or 
SFggguuu tables, the monitor determines which tables have been changed and 
refreshes its list of active file sets. The monitor then analyzes what changes have been 
made; the monitor can start or stop ASYSYNCP processes or simply send a new set of 
file sets to an existing ASYSYNCP process.
The monitor responds to STATUS requests by the AUTOSYNC Command Interpreter 
with the cached list of file sets and ASYSYNCP processes.
Each monitor process can manage up to 1024 ASYSYNCP processes.
ASYSYNCP process
The ASYSYNCP process receives the list of file sets that have been assigned to it from 
the monitor. It alters its process-access ID to the user ID that is associated with the file 