AutoTMF Software User's Guide (Update 12)
Installation and Basic Management
HP NonStop AutoTMF Software User’s Guide—429952-014
2-9
Update System Coldload Procedures
Update System Coldload Procedures
Once you alter the database files to be audited, the NonStop AutoTMF monitor process 
becomes a critical component of application availability. You must ensure that the 
monitor process is started whenever system maintenance has required it to be 
stopped. You should include the start of the monitor process with the other operational 
steps that normally follow a system cold load.
You should start the monitor process after TMF has been started but before starting 
Pathway or any application processes. Start the NonStop AutoTMF monitor process by 
using the following TACL command:
The user ID required to start the monitor also must have read access to SysDB and 
MapDB tables.
Install EMS templates
The file ZESCTMPL contains EMS templates for all events generated by the NonStop 
AutoTMF software. Please refer to the DSM Template Services Manual for instructions 
about installing system templates.
You can use the EMS filter file ESCFLTR with an EMS distributor to display NonStop 
AutoTMF events. 
Updating NonStop AutoTMF Software
1. Stop application programs and all processes that use the NonStop AutoTMF 
runtime library. In this case, display (and optionally stop) all programs that use the 
NonStop AutoTMF runtime library by using the INFO LIBRARY command.
2. Stop the NonStop AutoTMF monitor process by using the command STOP 
MONITOR.
3. Replace the NonStop AutoTMF software files as described above under Install 
NonStop AutoTMF Software Files.
4. If required, bind your application user libraries with the new NonStop AutoTMF 
runtime library. See Combining a User Library with the NonStop AutoTMF Runtime 
in Section 3, Preparing Programs.
5. If you need to preserve modification timestamps or preserve license attributes of 
object files when preparing programs, perform the necessary steps to make the 
new Escort CI a licensed program, as described in Preserving the Modification 
Timestamp of Object Files or in Preserving License Attribute when Preparing 
Privileged Programs in Section 3, Preparing Programs.
6. Install the new NonStop AutoTMF EMS templates.
RUN $TOOLS.AUTOTMF.ESCORT START MONITOR;