AutoTMF Software User's Guide (Update 15)
System Management
HP NonStop AutoTMF Software User’s Guide—429952-017
A-21
Executing Prepared Applications
The TRACE command can be secured to prevent exposure, as follows:
The global setting for SECURETRACE should be ON, which is the default; use the 
ALTER GLOBAL command to configure SECURETRACE. The SysDB should be 
secured to prevent unauthorized users from altering this setting.
When SECURETRACE is ON, the user who initiates a trace must be the process 
access ID of the processes that is being traced. Other processes will run normally 
and will not trace or enter debug.
In development and testing systems, or systems where security is not a major 
issue, you may wish to set SECURETRACE to OFF to facilitate problem analysis.
To trace KEYS or DATA (that is, produce a trace in which the images of data 
records accessed by the program are displayed), AutoTMF requires the trace file 
to be secured so that only the process access id of the process may read the file. 
This ensures that no unauthorized person can read the database records in the 
trace.
Executing Prepared Applications
Swap space
When an application process first opens a file, the AutoTMF runtime allocates an 
extended memory segment, which requires a disk swap file. Space allocation or 
volume security errors may cause the allocation to fail, which will terminate the 
application process.
The default location for a swap file is the volume on which the object file resides. If the 
space on that volume is insufficient, the user can allocate up to four alternate swap 
volumes using the global parameters SWAPVOL[0],SWAPVOL1, SWAPVOL2, 
SWAPVOL3. 
You can also set the global parameter KMSF to enable Kernel Managed Swap Facility 
(KMSF) allocation in the
See ALTER GLOBAL
 on page 6-35 for details about SWAPVOLn and KMSF 
parameters.
EMS Logging
In addition to being displayed on the home terminal of the application programs, the 
internal errors detected by the runtime are logged to an EMS collector. The default 
collector is $0. Logging to an alternate collector can be configured using the global 
parameter EMSCOLLECTOR or, if required on a process by process basis, by using a 
DEFINE. See ALTER GLOBAL on page 6-35 and =_ESCORT_EMS_COLLECTOR on 
page B-6 for details. 
The following EMS event management files are supplied with the AutoTMF product: