AWAN 3886 Server Installation and Configuration Guide

Introduction to AWAN 3886-Series Servers
AWAN 3886 Server Installation and Configuration Guide427428-006
1-6
AWAN 3886-16 Server (DECserver 716) 16
Asynchronous Ports
AWAN 3886-16 Server (DECserver 716) 16 Asynchronous Ports
Support for the 16-port 3886 AWAN server is as follows:
Sixteen asynchronous RS-232 ports with RJ45 connectors.
Flash ready with an external Flash RAM memory card.
Connection with the LAN by Ethernet, using 10BaseT or an AUI port.
Supports the 16-port RS-232 to Current Loop Converter
Note. The 3886-16 provides only partial modem-signal support. This partial modem-signal
support generally only affects certain GAP applications.
Figure 1-2. Front Panel of AWAN Server Model (DECserver 716)
1.
System reset switch. To restore factory settings, press and hold this switch during
power-up until the green OK LED starts flashing. This reloads the factory set
parameters and all customized parameters are lost.
2.
System OK LED. Lights when the AWAN server has power.
3.
Flash card slot. Provides an opening in which to insert the Flash RAM card.
4.
EIA-232 asynchronous serial ports. These 16 asynchronous 8-pin MJ ports connect
devices to the AWAN server.
5.
Seven-segment display. Provides error and status information:
Blinks: If an error occurs during self-test
Off: The AWAN server failed self-test
Rotating Figure ‘8’: Operating image loaded and running
See Seven-Segment LED Display and Codes
on page 3-6.
DECserver 716
#
#
LNK
8
1357 1510 12 14
24 68 1691113
1 2
3
4
5
6
7
8 9
10
11
12
vst16.vsd