AWAN 3886 Server Installation and Configuration Guide
Troubleshooting AWAN 3886 Servers
AWAN 3886 Server Installation and Configuration Guide—427428-006
3-8
Status: Flashing OK LED Problem: Transceiver
Loopback Error (1)
Using the SHOW AWAN command:
Local> SHOW AWAN
AWAN Features Enabled
Hardware Model 3886-8A
Software build 236
Vproc T0484 13Sep2003
CTRACE Not active
Config resets Factory and AWAN-3886
Status: Flashing OK LED
Problem: Transceiver Loopback Error (1)
After restoring power, the LNK PULSE LED light remains off.
AWAN status reported on port 1:
Note. Message 090 can vary, depending on your loaded software version.
Table 3-6. Transceiver Failure (1) - AWAN Not Connected to Hub
Problem Solution
AWAN not properly
connected to hub
Correct the connection between AWAN and hub
LED Indicator Seven-Segment Display:
OK LED light flashes;
LNK PULSE LED is OFF
Port 1 Error Message Transceiver Loopback error
Example 3-3. Port 1: Transceiver Loopback Error
Local -901- Initializing DECserver 716 00-00-F8-52-BB-7F FW V7.2-0 HW 1.7
Local -960- Available Memory 4 Mbytes
Local -941- Transceiver Loopback error
Local -952- Enter ^P to repeat selftest
d-E-d-b-H-4-b-5 -
OK LED light flashing