Binder Manual (G06.27+, H06.04+, J06.03+)

Binder Messages
Binder Manual528613-004
8-11
Error Messages and Warnings
50
You must establish a current file before the named commands can be executed. Either
reenter the command with the FROM file-name parameter or use the FILE
command. FILE establishes the default file for subsequent commands (or until another
FILE is entered).
51
You have specified a command parameter in a form that is not recognizable by the
HELP command. Use HELP command-name to verify the parameter forms. HELP with
no parameters lists all the Binder commands.
52
This error occurs on COBOL85 input files.
Binder encountered a CANCEL for the entry point name, but no CALL statement
referred to the entry point. Therefore, parameters could not be checked.
53
Word 32767 is used in the word-addressable data space. Binder cannot allocate the
stack. Reorganize the data space.
54
The external entry point table cannot be placed in the code space.
55
Three levels of nesting is the maximum allowed for OBEY files.
E No current file for ADD/REPLACE/LIST/DUMP
E No help available for name
W No parameter information provided for entry-name
E No space left for stack after data block
allocation
E Not enough space for XEP table; n words
required, m words available
E OBEY nesting exceeds maximum