III. Post-Installation Instructions
1. If you did not install the EMS template files using DSM/SCM,
invoke the INSTALL^TEMPLATES TACL macro to install the ZDOMTMPL
EMS template files contained on the CD. This TACL macro and
instructions for its use are given in Support Note S92067B
(updated 24AUG94), which you can obtain by using NTL or from Scout
for NonStop Servers. Starting with C30.09 and D20.00 releases, the
INSTALL^TEMPLATES TACL macro is distributed on the SUT and can be
found in <ISVvol>.ZINSAIDS.TACLMACS. To print the usage notes,
LOAD the file containing the macro and at the TACL prompt,
type: INSTALL^TEMPLATES /OUT <outdev>/HELP
2. If you placed the files using DSM/SCM, the product directories
will be owned by super.super. Logon as super.super in the OSS
environment and give the files to the preferred owner.
Log on as SUPER.SUPER
Start the OSS environment
Type this command:
chown -R user.user1 /usr/tandem/nsdoms
where user.user1 is the user ID that will own the
NonStop CORBA OSS files.
Check the security of the files in /usr/tandem/nsdoms to be sure
that it is compatible with your system management and organization
policies.
3. Use either the preferred workstation-based installer or NonStop
S-series based installer to complete the installation.
a) Use the workstation-based GUI installer, INSTALL_CORBA.EXE,
to install any or all of the following;
NonStop CORBA 2.6.1A Software Development Kit
NonStop CORBA 2.6.1A Run Time Kit
SSL for NonStop CORBA 2.6.1A
(from the CD) by double clicking on the program and
following the directions.
During an IPSetup installation of NonStop CORBA 2.6.1A, two
subvolumes are used for storing files on the HP NonStop
S-series platform. The first subvolume is a "Working
subvolume", that the installer uses to designate a location
for temporary files. The volume chosen for this "Working
subvolume" is also used by IPSetup to indicate the ultimate
location of the product ISV.
R2817C12 is the default DSV for NonStop CORBA 2.6.1A RTK.
R2818C12 is the default DSV for NonStop CORBA 2.6.1A SDK.
R2820C12 is the default DSV for SSL for NonStop CORBA 2.6.1A.
During final installation the target subvolume used for
storing the product files will be the volume assigned for
the "Working subvolume" and the appropriate product DSV,
R2817C12, R2818C12 and/or R2820C12.
For example, if the "Working subvolume", $DATA01.C12NPV is
selected, the product installation DSV for NonStop CORBA 2.6.1A
SDK will be $DATA01.R2818C12.
NOTE: In the case of a non default installation, the ISV
chosen for all components MUST be the same.
Page 3