Modifier Set for the ALTER LINE LIU Command
Modifier Set for the ALTER LINE LIU Command
The modifier set for the ALTER LINE LIU is one or more of the following modifier name
and value combinations. The modifiers are listed alphabetically and are described in
Section 7, LIU Protocol and Modifiers.
Examples of the ALTER LINE LIU Command
The following command alters the line $CPL1, including the WORD2 value:
->ALTER LINE $CPL1, LIU, WORD2 23
The following command alters the line $CPL1, including the OPCLASS value:
->ALTER LINE $CPL1, LIU, OPCLASS ASYNC
The following command alters the line $CPL1, including the WORD5, WORD1, and
WORD19 values:
->ALTER LINE $CPL1, LIU, WORD5 45, WORD1 64, WORD19 23
[ , opclass { ANY | ASYNC | BISYNC | BITSYNC } ]
[ , program file-name ]
[ , WORD0 { 0 through 32767 } ]
[ , WORD1 { 0 through 32767 } ]
[ , WORD2 { 0 through 32767 } ]
[ , WORD3 { 0 through 32767 } ]
[ , WORD4 { 0 through 32767 } ]
[ , WORD5 { 0 through 32767 } ]
[ , WORD6 { 0 through 32767 } ]
[ , WORD7 { 0 through 32767 } ]
[ , WORD8 { 0 through 32767 } ]
[ , WORD9 { 0 through 32767 } ]
[ , WORD10 { 0 through 32767 } ]
[ , WORD11 { 0 through 32767 } ]
[ , WORD12 { 0 through 32767 } ]
[ , WORD13 { 0 through 32767 } ]
[ , WORD14 { 0 through 32767 } ]
[ , WORD15 { 0 through 32767 } ]
[ , WORD16 { 0 through 32767 } ]
[ , WORD17 { 0 through 32767 } ]
[ , WORD18 { 0 through 32767 } ]