CP6100 Configuration and Management Manual
Managing CP6100 Using the Subsystem
Control Facility (SCF)
CP6100 Configuration and Management Manual—426741-003
8-24
Considerations for the STATS Command
Output Errors
is the number of output errors at the LIU level.
Considerations for the STATS Command
•
If RESET is specified, all statistical counters are reset.
•
The STATS command alone is not a sensitive command. However, the STATS
command with the RESET option is sensitive.
Examples of the STATS Command
The following SCF command displays the statistical information for the LINE $CPL1:
- > STATS LINE $CPL1
The following SCF command resets statistics counters for the line $CPL1:
- > STATS LINE $CPL1, RESET