4 ADCCP Protocol and Modifiers
This section gives a brief overview of the ADCCP protocol and describes the modifiers
you can use to modify the functions of an ADCCP communications line.
PCP6ADCP Profile
The PCP6ADCP profile configures the line for the Advanced Data Communications
Control Procedure (ADCCP) protocol, which is a bit-synchronous data communications
line protocol developed by the American National Standards Institute (ANSI) and
defined in ANSI Standard X3.66-1979. Table 4-1 lists the default modifiers and values
for the PCP6ADCP profile provided by HP.
Note. To use the X.21 interface for ADCCP, specify C8169P20 as the PROGRAM modifier.
Table 4-1. PCP6ADCP Default Modifiers and Values
Modifier Default Value Modifier Default Value
AUTOCONF STATIONS
1
AUTOLOAD
TRANSLATE
AUTOCLOSE XOFFSET 0
MAXLOCALAREA 8200 XLENGTH 0
LOCALPOOLPAGES 60 POLL
CLBFRAMESIZE 256 TWS
CMGLDEV 0 WINDOW 3
BITSYNC SWINCARRIER
PROGRAM C8169P00 L2RETRY 3
TESTINT 1000 L1RETRY 3
CLBRETRIES 4 THRESHOLD 500
CLBWINDOW 1 XFERTIMER 100
CLBTIMEOUT 3000 T1TIMER 100
TIMEOUT 3000 IDLETIMER 100
RETRIES 3 DSRTIMER 300
CLIPTRACEREC 32 ADDRESS0 0
CONFIGSIZE 20 ADDRESS1 0
MAXFRAME 256 ADDRESS2 0
NRMMODE ADDRESS3 0
AFLD 1 PROFILE Depends on IPM