CP6100 Configuration and Management Manual

ADCCP Protocol and Modifiers
CP6100 Configuration and Management Manual426741-003
4-4
ADCCP Modifiers
ARMMODE
See ABMMODE, ARMMODE, or NRMMODE on page 4-2.
AUTOCLOSE
This modifier specifies that CP6100 CAP will CLOSE all file system OPENs if the CLIP
must be downloaded for error-recovery.
AUTOCONF
This modifier causes the CP6100 line-handler process to send the current
configuration block to the line interface unit (LIU) on the first OPEN (that is, when
OPEN count goes from 0 to 1) after a download.
AUTOLOAD
This modifier specifies that the CLIP software is to be automatically downloaded if the
CLIP sends a STATUS PROBE message with a status error greater than 1.
BITSYNC
This modifier is an operational class modifier that specifies the operational class of the
LIU download module as bit-synchronous. If an appropriate module is not found in the
Default: AUTOCLOSE
Units: None
See
also:
NOAUTOCLOSE
Default: AUTOCONF
Units: None
Range: N/A
See
also:
NOAUTOCONF on page 4-10
Default: AUTOLOAD
Units: None
See
also:
NOAUTOLOAD
Note. AUTOLOAD will prevent you from obtaining a CLIP dump if the CLIP crashes, because
the autoload will occur before the dump can be obtained.
Default: BITSYNC
Units: None