CP6100 Configuration and Management Manual
ADCCP Protocol and Modifiers
CP6100 Configuration and Management Manual—426741-003
4-9
ADCCP Modifiers
L2RETRY n
This modifier specifies the number of times the ADCCP protocol requests an
acknowledgment when the remote station does not respond to a link command or a
poll (that is, when the T1TIMER expires). This modifier does not apply to the mode-
setting commands such as Set Normal Response Mode (SNRM), Set Asynchronous
Balanced Mode (SABM), Set Initialization Mode (SIM), and Disconnect (DISC). Mode-
setting commands are tried twice. (Mode-setting commands are used to establish,
initialize, and shut down the data link.)
LOCALPOOLPAGES n
This modifier specifies the number of pages obtainable from the local pool. The default
value allows optimum resource use for most systems.
MAXFRAME n
This modifier specifies the maximum number of information field (I-field) bytes that can
be sent or received over the line. The value sets the size of the I-field only. It does not
include the address field, the control field, or the frame-check sequence.
MAXLOCALAREA n
This modifier specifies the largest buffer obtainable from the local pool.
Default: n = 3
Units: None
Range: 0 through 255
Default: 60
Units: 1024-word pages
Range: 0 to 63
Default: n = 256
Units: Bytes
Range: 75 through 3222 (SWAN - RS232 interface)
Default: 8200
Units: Words
Range: 1024 through 32767