CP6100 Configuration and Management Manual

ADCCP Protocol and Modifiers
CP6100 Configuration and Management Manual426741-003
4-16
ADCCP Modifiers
TESTINT
This modifier specifies the interval for probing the status of the line. A value of zero
means the line is never probed.
THRESHOLD n
This modifier specifies the transmit and receive frame count that triggers the
asynchronous reporting of line quality statistics. If the value is 0, the
LINE_QUALITY_RSP is never sent to CSS ADCCP as a result of frame counts.
TIMEOUT
This modifier specifies the interval that the I/O process is to wait for a response to a
request before retrying.
TRANSLATE
This modifier specifies that the frame I-field is to be translated from EBCDIC to ASCII
during transmissions between the line and the host. By default, translation occurs.
To select a portion of the I-field to translate, also use the XOFFSET and XLENGTH
modifiers.
Default: 1000
Units: .01 seconds
Range: 0 through 32767
Default: n = 500
Units: None
Range: 100 through 32767
Note. The THRESHOLD modifier has no effect and is maintained for compatibility with older
systems.
Default: 3000
Units: .01 seconds
Range: 0 through 32767
Default: TRANSLATE
Units: None
Range: N/A
See
also:
NOTRANSLATE on page 4-11, SNAXLATE on page 4-13, XOFFSET n