CP6100 Configuration and Management Manual
ADCCP Protocol and Modifiers
CP6100 Configuration and Management Manual—426741-003
4-18
ADCCP Modifiers
WINDOW n 
This modifier specifies the maximum number of I-frames that can be sent without 
receiving an acknowledgment. The value of WINDOW depends on the value of the 
MAXFRAME modifier.
XFERTIMER n 
This modifier specifies a timer interval for the level-1 protocol. The timer clocks the 
interval to wait until the transmission of a frame should be complete. The timer is 
started when frame transmission starts with the raising of RTS, and is cleared when 
frame output is completed. The value must be for an interval that is longer than the 
sum of the following:
•
The transmission of a frame with an I-field of MAX_FRAME_SIZE bytes at the rate 
of speed of the link
•
The clear-to-send (CTS) delay for the modem
XLENGTH n 
This modifier specifies the number of bytes of the I-field to be translated, starting at the 
offset specified by XOFFSET. A value of 0 causes all bytes from the offset to the end 
of the I-field to be translated. 
Default: n = 3
Units: None
Range: 1 through 7 (basic control mode)
1 through 127 (extended control mode)
See 
also:
MAXFRAME n on page 4-9
Default: n = 100
Units: .01 seconds
Range: 10 through 32767
Default: n = 0
Units: Bytes
Range: 0 through 2046
See 
also:
TRANSLATE on page 4-16, and XOFFSET n on page 4-19