CP6100 Configuration and Management Manual

BSC Protocol and Modifiers
CP6100 Configuration and Management Manual426741-003
5-7
BSC Modifiers
BSCPPSW
This modifier specifies a switched line. For switched lines, CP6100 sends a DLE EOT
and drops the DTR signal when a disconnect or stop line request is received. When a
DLE EOT is received, CP6100 drops the DTR signal and rejects I/O requests. When
the DTR signal is cleared, CP6100 waits until the DSR signal drops or a timeout
occurs.
BSCPTPT
This modifier specifies that the protocol is point-to-point bisynchronous. By default, the
protocol is HASP multileaving.
BSCREADTO n
This modifier specifies the amount of time to wait for the next block of text during a
READ operation before reporting an error condition to the application.
BSCRETRIES n
This modifier specifies the number of times an operation (such as a line bid, write, or
read [bad CRC]) is retried before an error condition is reported to the application.
Default: BSCPPNSW
Units: None
Range: N/A
Default: HASP multileaving
Units: None
Range: N/A
Default: 3000
Units: .01 seconds
Range: 0 through 32767
Default: 7
Units: None