CP6100 Configuration and Management Manual

BSC Protocol and Modifiers
CP6100 Configuration and Management Manual426741-003
5-8
BSC Modifiers
BSCSECONDARY
This modifier specifies the station as a secondary station. By default, the station is
primary.
BSCSYNCS n
This modifier specifies the number of SYN characters that precede a transmission.
This number includes the initial PAD characters that begin and end each message.
BYTESYNC
This modifier is an operational class modifier that specifies the operational class of the
LIU download module as byte-synchronous. If an appropriate module is not found in
the download file, the operation terminates. BYTESYNC is the default operational class
for the PCP6BSC profile.
When the BYTESYNC modifier is included in the PROFILE file, the ConMgr process
checks to make sure that the operational modifier specified in the microcode file
matches line configuration. If they do not match, the microcode download does not
occur; however, you will not receive an SCF error. If the operational modifier does not
match the line configuration, you will receive a system error stating that the microcode
was not downloaded after the attempted download to the CLIP.
Default: Primary station
Units: None
Range: N/A
Default: 3
Units: None
Range: 3 through 255
Default: BYTSYNC
Units: None