MPS-B Modifiers
AUTOLOAD
This modifier specifies that the CLIP software is to be automatically downloaded if the
CLIP sends a STATUS PROBE message with a status error greater than 1.
CLBFRAMESIZE n
This modifier changes the framesize sent to the CLIP. The value n specifies the
maximum number of words to be transferred in a frame.
If you specify a value larger than the range, the software changes the value to the
maximum allowed. Likewise, if you specify a value smaller than the range, the software
uses the minimum value.
CLBRETIRES n
This modifier specifies the number of retires for requests. The value n is the number of
tries.
CLBTIMEOUT n
This modifier specifies the timeout. The value n is the length of time before a timeout
occurs.
Default: AUTOLOAD
Units: None
See
also:
NOAUTOLOAD
Note. AUTOLOAD will prevent you from obtaining a CLIP dump if the CLIP crashes, because
the autoload will occur before the dump can be obtained.
Default: 128
Units: Words
Range: 150 through 600
See
also:
CLIPTRACEREC n on page 6-4
Default: 4
Units: None
Range: 0 through 63
Default: 3000
Units: 0.01 seconds
Range: 0 through 32767