CP6100 Configuration and Management Manual

MPS-B Protocol and Modifiers
CP6100 Configuration and Management Manual426741-003
6-7
MPS-B Modifiers
MPSBCHARACTERSIZE n
This modifier specifies the number of bits that make up a character during
transmission. The recommended character size for even and odd parity is 7. For no
parity, it is 8. If you specify a character size of 0, the character size is 7.
MPSBCONNECTTIMEOUT n
This modifier specifies the time interval that the LIU is to wait for DSR to appear
following a start command for leased lines or a modem control connect command for
switched lines. If DSR does not appear before the interval expires, the function is
terminated and DTR is reset. The default timeout is 30 seconds. If n is 0, no interval
occurs and the LIU waits indefinitely for DSR.
MPSBCONTROLCF
This modifier specifies that the line is to be turned around (that is, data is transmitted)
after DCD drops.
MPSBEVEN
This modifier specifies even parity-checking for the line.
Default: 7 (parity not included)
Units: Bits
Range: 0 through 8
Default: 3000 (30 seconds)
Units: .01 seconds
Range: 0 through 32767
Default: MPSBCONTROLCF
Units: None
Range: N/A
Default: MPSBEVEN
Units: None
Range: N/A
See
also:
MPSBODD on page 6-9