LIU Modifiers
AUTOCLOSE
This modifier specifies that CP6100 CAP will CLOSE all file system OPENs if the CLIP
must be downloaded for error-recovery.
AUTOCONF
This modifier causes the CP6100 line-handler process to send the current
configuration block to the line interface unit (LIU) on the first OPEN (that is, when
OPEN count goes from 0 to 1) after a download.
For the PCP6LIU profile, you must also specify LIUCONFIG00 10 when AUTOCONF is
used.
AUTOLOAD
This modifier specifies that the CLIP software is to be automatically downloaded if the
CLIP sends a STATUS PROBE message with a status error greater than 1.
Default: AUTOCLOSE
Units: None
See
also:
NOAUTOCLOSE on page 7-8
Default: NOAUTOCONF
Units: None
Range: N/A
See
also:
NOAUTOCONF on page 7-8
Default: AUTOLOAD
Units: None
See
also:
NOAUTOLOAD on page 7-9
Note. AUTOLOAD will prevent you from obtaining a CLIP dump if the CLIP crashes, because
the autoload will occur before the dump can be obtained.