CP6100 Configuration and Management Manual
LIU Protocol and Modifiers
CP6100 Configuration and Management Manual—426741-003
7-3
LIU Modifiers
AUTOCLOSE 
This modifier specifies that CP6100 CAP will CLOSE all file system OPENs if the CLIP 
must be downloaded for error-recovery.
AUTOCONF 
This modifier causes the CP6100 line-handler process to send the current 
configuration block to the line interface unit (LIU) on the first OPEN (that is, when 
OPEN count goes from 0 to 1) after a download.
For the PCP6LIU profile, you must also specify LIUCONFIG00 10 when AUTOCONF is 
used.
AUTOLOAD 
This modifier specifies that the CLIP software is to be automatically downloaded if the 
CLIP sends a STATUS PROBE message with a status error greater than 1. 
Default: AUTOCLOSE
Units: None
See 
also:
NOAUTOCLOSE on page 7-8
Default: NOAUTOCONF
Units: None
Range: N/A
See 
also:
NOAUTOCONF on page 7-8
Default: AUTOLOAD
Units: None
See 
also:
NOAUTOLOAD on page 7-9
Note. AUTOLOAD will prevent you from obtaining a CLIP dump if the CLIP crashes, because 
the autoload will occur before the dump can be obtained.