CP6100 Configuration and Management Manual
LIU Protocol and Modifiers
CP6100 Configuration and Management Manual—426741-003
7-4
LIU Modifiers
BITSYNC
This modifier is an operational class modifier that specifies the operational class of the
LIU download module as bit-synchronous. If an appropriate module is not found in the
download file, the operation terminates. BITSYNC is the default operational class for
the PCP6ADCP profile.
When the BITSYNC modifier is included in the PROFILE file, the ConMgr process
checks to make sure that the operational modifier specified in the microcode file
matches the line configuration. If they do not match, the microcode download does not
occur; however, you will not receive an SCF error. If the operational modifier does not
match the line configuration, you will receive a system error stating that the microcode
was not downloaded after the attempted download to the CLIP.
BYTESYNC
This modifier is an operational class modifier that specifies the operational class of the
LIU download module as byte-synchronous. If an appropriate module is not found in
the download file, the operation terminates. BYTESYNC is the default operational class
for the PCP6BSC profile.
When the BYTESYNC modifier is included in the PROFILE file, the ConMgr process
checks to make sure that the operational modifier specified in the microcode file
matches line configuration. If they do not match, the microcode download does not
occur; however, you will not receive an SCF error. If the operational modifier does not
match the line configuration, you will receive a system error stating that the microcode
was not downloaded after the attempted download to the CLIP.
Default: ANY
Units: None
Range: N/A
See
also:
ASYNC on page 7-2, and BYTESYNC on page 7-4
Default: ANY
Units: None
Range: N/A
See
also:
ASYNC on page 7-2, and BITSYNC on page 7-4