CP6100 Configuration and Management Manual

LIU Protocol and Modifiers
CP6100 Configuration and Management Manual426741-003
7-5
LIU Modifiers
CLBFRAMESIZE n
This modifier changes the framesize sent to the CLIP. The value n specifies the
maximum number of words to be transferred in a frame.
If you specify a value larger than the range, the software changes the value to the
maximum allowed. Likewise, if you specify a value smaller than the range, the software
uses the minimum value.
CLBRETIRES n
This modifier specifies the number of retires for requests. The value n is the number of
tries.
CLBTIMEOUT n
This modifier specifies the timeout. The value n is the length of time before a timeout
occurs.
CLBWINDOW n
This modifier specifies the number of read buffers allocated. The value n is the size of
the window.
Default: 256 words
Units: Words
Range: 150 through 600 (for LIU-1)
See
also:
CLIPTRACEREC n on page 7-6
Default: 4
Units: None
Range: 0 through 63
Default: 3000
Units: 0.01 seconds
Range: 0 through 32767
Default: 1
Units: Read buffers
Range: 1 through 8