CP6100 I/O Process Programming Manual

Using CP6100: Managing Lines
-----------------------------------------------------------------
| |
| CONTROLLERS: |
| |
| !Name Product # CPUs Subchannels Modifiers |
| CIU1 6101 4,5 %40 ; |
| CIU2 6101 5,4 %100 ; |
| |
| PATHS: |
| |
| !Path Controller Modifiers |
| !Name Names |
| COMMA CIU1-CIU2 ALTERNATE_PATH COMMB; |
| |
| |
| MICROCODE_FILES: |
| |
| C9304P00 $SS10.CSSCIU.C9304P00; !for CIU |
| C9310P00 $SS10.CSS10.C9310P00; !for BSC |
| C9312P00 $SS10.CSS10.C9312P00; !for ADCCP |
| |
| |
| PERIPHERALS: |
| |
| !Device Name.number Product # Modifiers |
| !Name or name |
| |
| $CSM1 COMMA.0 CSM ; |
| $BSC1 COMMA.2 BISYNC TYPE 51, SUBTYPE 01, |
| RSIZE 80, NOCONF; |
| $HDLC1 COMMB.1 ADCCP TYPE 51, SUBTYPE 02, |
| RSIZE 80, MAXFRAME 256,|
| ABMMODE, AFLD2, |
| EXTENDED, SREJOK, |
| POLL, WINDOW 12, |
| ADDRESS0 %100, |
| ADDRESS1 %101; |
| |
-----------------------------------------------------------------
| Figure 3-1a. Sample Entries from SYSGEN Configuration File
| (Dual-Port Controllers)
October 1985