CP6100 I/O Process Programming Manual
 Using CP6100: Managing Lines
 ALTER LINE <ldev>, OPCLASS
 This command determines the range of protocols an LIU will
 accept. Given the current product offering, the reasonable
 values are BISYNC (if you're going to use the BSC, TINET, or MPSB
 protocol), BITSYNC (if you're going to use the ADCCP protocol),
 or ANY (if you plan to use both kinds of protocol on the same
 line). The command is required if you wish to change from one
 type of link to another.
 This command takes effect when the line is downloaded; it
 lasts until the next cold-load or the next time you give the
 command.
 Examining the Configuration
 For each ALTER command in the preceding pages, CMI has an INFO
 command to let you inspect the current values. The INFO command
 is legal, regardless of the state of the line, but can supply
 some information only if the LIU has been downloaded. (For
 example, if the LIU has not been downloaded, INFO can't retrieve
 any data from the configuration block.)
 INFO LINE <ldev>, PROGRAM
 This command displays the name of the file that will be
 downloaded to the LIU unless the operator specifies another name
 in the START command.
 INFO LINE <ldev>, CONFIG
 If the line is started, this command displays the values in the
 configuration block in the LIU. If the line is stopped and
 AUTOCONF is specified, this command displays the values in the
 template block maintained by CP6100. You can specify an offset
 into the block to see the value of one parameter.
 October 1985
 3-16










