CP6100 I/O Process Programming Manual
 Using CP6100: Managing Lines
 INFO LINE <ldev>, OPCLASS
 This command displays the range of protocols the line will
 accept. The possible values are BISYNC, BITSYNC, or ANY.
 If the line has not been downloaded since the last ALTER LINE
 <ldev>, OPCLASS command, the OPCLASS value might be inconsistent
 with the running protocol. For example, if an LIU were running
 BISYNC and you changed the OPCLASS to BITSYNC, the restriction
 would not take effect until the next download.
 INFO LINE <ldev>, DETAIL
 This command displays all of the above information, plus the
 value, on or off, of a state called DEBUG, which tells you
 whether a Tandem analyst is using special software to debug the
 line. (The software is a nonsymbolic debugger called CSSDBUG.)
 The line must be started for this command to work.
 October 1985
 3-17