CP6100 I/O Process Programming Manual

Using CP6100: Managing Lines
INFO LINE <ldev>, OPCLASS
This command displays the range of protocols the line will
accept. The possible values are BISYNC, BITSYNC, or ANY.
If the line has not been downloaded since the last ALTER LINE
<ldev>, OPCLASS command, the OPCLASS value might be inconsistent
with the running protocol. For example, if an LIU were running
BISYNC and you changed the OPCLASS to BITSYNC, the restriction
would not take effect until the next download.
INFO LINE <ldev>, DETAIL
This command displays all of the above information, plus the
value, on or off, of a state called DEBUG, which tells you
whether a Tandem analyst is using special software to debug the
line. (The software is a nonsymbolic debugger called CSSDBUG.)
The line must be started for this command to work.
October 1985
3-17