CP6100 I/O Process Programming Manual
 File System Error Codes
 ----------------------------------------------------------------
 THESE ARE SERIOUS. DON'T RETRY.
 ----------------------------------------------------------------
 2 Invalid operation requested. You probably issued a
 call CP6100 doesn't support. Remember to use
 WRITEREADs for all requests to the line.
 ----------------------------------------------------------------
 12 Device has been opened exclusively. The device is
 in use by another application. If other
 applications use the line, or if your application
 opens the line more than once, make sure you specify
 shared access in every OPEN call. If another
 application has the line open exclusively, you must
 wait until that application closes the line.
 ----------------------------------------------------------------
 14 Device does not exist. The line you named is not
 known to the system. Check your spelling, and make
 sure the name is properly qualified, i.e., that the
 system name is correct.
 ----------------------------------------------------------------
 21 Invalid count field in request. This message can
 mean that:
 • The READ or WRITEREAD buffer is too small. It
 must be at least eight bytes long.
 • The write count parameter in the WRITEREAD call
 is not equal to the value in the Textout field
 plus 8.
 • The read count parameter in the WRITEREAD call
 is not at least equal to the value in the Textin
 field plus 8.
 • The protocol task made an error in its response
 to CP6100, by delivering more or fewer characters
 than it said it was delivering, or by reporting a
 frame size that doesn't match the application
 request.
 First check your program to see that your file
 system call was valid. If you suspect the protocol
 task to be at fault, ask the system operator to stop
 the line and download the line interface unit. If
 the problem persists, contact your Tandem
 representative.
 ----------------------------------------------------------------