CP6100 I/O Process Programming Manual
 File System Error Codes
 -----------------------------------------------------------------
 124 Indicates that a line reset is in progress. An
 application receiving an error 124 should retry the
 operation.
 When a path switch occurs in a vertical
 configuration (where the twi paths to the CIU are on
 the same CPU), error 124 is returned and the
 application should retry the operation.
 When a path switch occurs in a diagonal
 configuration (where the 2 paths to the CIU are on
 different CPUs) error 210 is returned and the
 application should retry the operation.
 Error 124 is also returned when a controller or CLIP
 is powerfailed. In the event of a CLIP powerfail, a
 download of the CLIP is done with three download
 retries. If the download retry counts have been
 exhausted (at least 2 minutes), the line will be
 declared down and an error 66 will be returned
 to all pending requests.
 ----------------------------------------------------------------
 200 Device Owned by Other CPU. *
 210 Path Switch Occurred. *
 211 CPU Failure. *
 230 CPU Power On. *
 231 Controller power on, channel reset, or loss of *
 contact with the 6100 subsystem cabinet. See
 the discussion of "Total Subsystem and LIU
 Failures" in this Appendix.
 * These messages indicate that a path switch has occurred or
 is occurring. See the discussion of path switches in this
 Appendix.
 -----------------------------------------------------------------
 A-9










