Data Transformation Engine Integration Flow Designer Reference Guide
Chapter 6 - Map Components  Working with Map Components 
Integration Flow Designer Reference Guide 
93 
TimeEvent Setting  Description 
♦  0 - The 0 setting is used to omit the 0 hour 
(midnight to 1:00 am). The default value for 
the 0 setting is 
No. 
♦  1 through 23 - These settings work the same 
way as the 0 setting (above). 
SkipIfBusy  Use the SkipIfBusy setting to ignore the time event 
trigger if it occurs when a watch instance is already in 
process. The default value is Yes. 
EventCoordination  Use the EventCoordination setting to control the 
coordination of time event and input event triggers. The 
EventCoordination setting is available only if the map 
has both a time event trigger and one or more input 
event triggers; and the SourceEvent setting for one of 
the input cards is ON. The input event trigger can have 
wildcards. The default value for the EventCoordination 
setting is FirstAvailable. 
Pending Instance Thresholds 
The Pending Instance Thresholds enables a listener to pause or resume for a 
specific watch. 
Setting Description 
Hi  Value (no limit) for the watch to pause the event(s) for that watch. 
The default value is 0. 
Low  Value (no limit) for the watch to resume the event(s) for that watch. 
The default value is 0. 
Note If the InitPendingHigh and InitPendingLow settings in the Launcher section of 
the mercator.ini file are also set, the Pending Instance Thresholds Event 
Server settings will take precedence. 