Data Transformation Engine Map Designer Reference Guide

Chapter 5 - Card Settings Input and Output Card Settings
Map Designer Reference Guide
95
Input and Output Card Settings
The Retry and the Backup settings appear on both input and output cards.
Retry
The Retry settings are defined for each input and output card. The Retry setting is
compiled into the map, but may be overwritten by the execution settings defined
in the Integration Flow Designer and the AdapterRetry (
-Y) execution command.
If adapter errors occur (for example, failure to connect) and Retry > Switch =
On, the adapter process is retried at the interval specified with the Interval value
up to as many times as defined with the MaxAttempts setting.
The Retry settings specify the number of times and the interval at which to
attempt access an unavailable source or target.
Define the Retry settings for each input (or output) card as required.
Retry > Switch
The Switch setting determines whether Retry for the specific adapter is ON or
OFF. The default value of the Switch setting is OFF.
Value Description
OFF Retry is inactive. No attempt is made to access an unavailable
source or target.
ON Retry is active. Attempts are made to access an unavailable
source or target for the number of attempts specified with
MaxAttempts and at the time interval specified with
Interval.