Data Transformation Engine Type Tree Importers Reference Guide
Appendix A – Return Codes and Error Messages  COBOL Copybook 
Type Tree Importers Reference Guide 
57 
Return Code  Message 
9  Target not available 
This may be a security/authorization problem. Verify that you 
have authorization for read access for the input copybook file and 
write access for the specified output directory and the Mercator 
install directory. 
10 Internal error 
Contact Mercator Technical Support. 
11  Could not build one or more outputs 
An attempt may have been made to write to a read-only 
directory, an output file directory may be missing, or there may 
not be sufficient disk space on the output drive. 
12  Source not available 
An incorrect file name or path for the copybook input file may 
have been specified. 
13  Could not open work files 
There may not be sufficient disk space on the drive where the 
install directory exists to create necessary importer work files. 
15  Map must be recompiled 
You may have an outdated version of the importer maps versus 
the installed version of the Command Server. Re-install the 
correct version of the importer. 
16  Disk write error 
An attempt may have been made to write to a read-only directory 
or file. Also, check the amount of available disk space. 
17  Disk read error 
An attempt may have been made to access a file on a shared 
resource that is not accessible. Also, check the amount of 
available disk space. 
18  Page usage count error 
An internal paging problem exists. Contact Mercator Technical 
Support. 
19  Internal calling error 
Contact Mercator Technical Support. 










