Debug Manual
Table Of Contents
- What’s New in This Manual
- About This Manual
- 1 Introduction
- Execution Modes on TNS/R Systems
- What User Access Is Required for Debugging
- How to Make a Process Enter Debug
- How to Select Debug as the Debugger
- Why a Process Enters Debug
- How to Determine Process State on a Trap or Signal
- Ending a Debug Session
- What Appears in the Debug Header Message
- How to Use Debug
- How Debug Breakpoints Work
- 2 Using Debug on TNS/R Processors
- 3 Debug Command Overview
- 4 Debug Commands
- Command Summary
- A Command
- AMAP Command
- B Command
- BASE Command
- BM Command
- C Command
- CM Command
- D Command
- DJ Command
- DN Command
- EX[IT] Command
- F[ILES] Command
- FC Command
- FN Command
- FNL Command
- FREEZE Command
- HALT Command
- H[ELP] Command
- I Command
- IH Command (TNS/R Native and OSS Processes)
- INSPECT Command
- LMAP Command
- M Command
- MH Command (TNS/R Native and OSS Processes)
- P[AUSE] Command
- PMAP Command (Accelerated Programs)
- PRV Command
- R Command
- S[TOP] Command
- T Command
- V Command
- VQ Command
- VQA Command
- = Command
- ? Command
- A Error Messages
- B ASCII Character Set
- C Command Syntax Summary
- Register Syntax
- Expression Syntax
- Address Syntax
- A Command
- AMAP Command
- B Command
- BASE Command
- BM Command
- C Command
- CM Command
- D Command
- DJ Command
- DN Command
- EX[IT] Command
- F[ILES] Command
- FC Command
- FN Command
- FNL Command
- FREEZE Command
- HALT Command
- H[ELP] Command
- I Command
- IH Command
- INSPECT Command
- LMAP Command
- M Command
- MH Command
- Output-Device Syntax
- P[AUSE] Command
- PMAP Command
- PRV Command
- R Command
- S[TOP] Command
- T Command
- V Command
- VQ Command
- VQA Command
- = Command
- ? Command
- D Session Boundaries
- E Correspondence Between Debug and Inspect Commands
- F Sample Debug Sessions
- Glossary
- Index

Error Messages
Debug Manual—421921-003
A-6
23
23
Cause. The specified output device was invalid.
Effect. The command is not executed.
Recovery. Specify a valid output device and try again.
24
Cause. The name of the output device was not found, or the name was identified as a
disk device.
Effect. The command is not executed.
Recovery. Make sure that an output device is specified and that it is not a disk device.
25
Cause. A comma ( , ) needs to be specified after the space ID and before the offset.
Effect. The command is not executed.
Recovery. Specify the comma and try again.
26
Cause. The specified space ID is larger than the number of spaces available in the
code file. The code file has a maximum of 31 spaces (decimal).
Effect. The command is not executed.
Recovery. Check the number of code spaces in the listing of the code file. (The space
number is usually specified in octal.) Make sure that the number is not larger than what
is available for use.
Specified device name is invalid.
Output device is missing or output is directed to disk.
Comma (,) expected.
Space ID number is too large.