Table Of Contents
- What’s New in This Manual
- About This Manual
- 1 Introduction
- Execution Modes on TNS/R Systems
- What User Access Is Required for Debugging
- How to Make a Process Enter Debug
- How to Select Debug as the Debugger
- Why a Process Enters Debug
- How to Determine Process State on a Trap or Signal
- Ending a Debug Session
- What Appears in the Debug Header Message
- How to Use Debug
- How Debug Breakpoints Work
- 2 Using Debug on TNS/R Processors
- 3 Debug Command Overview
- 4 Debug Commands
- Command Summary
- A Command
- AMAP Command
- B Command
- BASE Command
- BM Command
- C Command
- CM Command
- D Command
- DJ Command
- DN Command
- EX[IT] Command
- F[ILES] Command
- FC Command
- FN Command
- FNL Command
- FREEZE Command
- HALT Command
- H[ELP] Command
- I Command
- IH Command (TNS/R Native and OSS Processes)
- INSPECT Command
- LMAP Command
- M Command
- MH Command (TNS/R Native and OSS Processes)
- P[AUSE] Command
- PMAP Command (Accelerated Programs)
- PRV Command
- R Command
- S[TOP] Command
- T Command
- V Command
- VQ Command
- VQA Command
- = Command
- ? Command
- A Error Messages
- B ASCII Character Set
- C Command Syntax Summary
- Register Syntax
- Expression Syntax
- Address Syntax
- A Command
- AMAP Command
- B Command
- BASE Command
- BM Command
- C Command
- CM Command
- D Command
- DJ Command
- DN Command
- EX[IT] Command
- F[ILES] Command
- FC Command
- FN Command
- FNL Command
- FREEZE Command
- HALT Command
- H[ELP] Command
- I Command
- IH Command
- INSPECT Command
- LMAP Command
- M Command
- MH Command
- Output-Device Syntax
- P[AUSE] Command
- PMAP Command
- PRV Command
- R Command
- S[TOP] Command
- T Command
- V Command
- VQ Command
- VQA Command
- = Command
- ? Command
- D Session Boundaries
- E Correspondence Between Debug and Inspect Commands
- F Sample Debug Sessions
- Glossary
- Index

About This Manual
Debug Manual—421921-003
xx
Notation for Management Programming Interfaces
% Percent Sign. A percent sign precedes a number that is not in decimal notation. The
% notation precedes an octal number. The %B notation precedes a binary number.
The %H notation precedes a hexadecimal number. For example:
%005400
%B101111
%H2F
P=%p-register E=%e-register
Notation for Management Programming Interfaces
This list summarizes the notation conventions used in the boxed descriptions of
programmatic commands, event messages, and error lists in this manual.
UPPERCASE LETTERS. Uppercase letters indicate names from definition files. Type these
names exactly as shown. For example:
ZCOM-TKN-SUBJ-SERV
lowercase letters. Words in lowercase letters are words that are part of the notation,
including Data Definition Language (DDL) keywords. For example:
token-type
!r. The !r notation following a token or field name indicates that the token or field is
required. For example:
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING. !r
!o. The !o notation following a token or field name indicates that the token or field is
optional. For example:
ZSPI-TKN-MANAGER token-type ZSPI-TYP-FNAME32. !o
Change Bar Notation
Change bars are used to indicate substantive differences between this manual and its
preceding version. Change bars are vertical rules placed in the right margin of changed
portions of text, figures, tables, examples, and so on. Change bars highlight new or
revised information. For example:
The message types specified in the REPORT clause are different in the COBOL
environment and the Common Run-Time Environment (CRE).
The CRE has many new message types and some new message type codes for
old message types. In the CRE, the message type SYSTEM includes all messages