Distributed Name Service (DNS) Management Operations Manual

DNSCOM Error Messages
B–6 31258 Tandem Computers Incorporated
Error 35 ERROR 35 - Required Parameter Not Supplied -
parameter
The current ADD command is rejected because the required indicated
parameter
was not previously set with the SET command.
Error 36 ERROR 36 - DNSCOM/DNSMGR Error - Routing Error
The current command is rejected because DNSCOM passed an SSID other than ZDNS-
VAL-SSID in an SPI buffer header. This error should be reported to your Tandem
representative.
Error 37 ERROR 37 - Primary Name Manager Failure During Transaction
The current command is aborted due to the failure of the name manager’s primary
process.
Error 38 ERROR 38 - Name Manager cannot locate System -
system
The current command failed because the indicated
system
is not visible from the
name manager’s system.
Error 39 ERROR 39 - Security Violation
Based on the current DNSOWNER and SECURITY settings, you are not allowed to
perform the requested operation.
Error 40 ERROR 40 - Wrong Number of Components
The current ADD COMPOSITE command failed because the number of components
supplied differs from the number of components for the associated composite type.
Error 41 ERROR 41 - Component Type Error -
name