DSM/SCM Event Management Programming Manual

Event Messages
DSM/SCM Event Management Programming Manual529844-003
5-71
2101 ZPHI-EVT-NO-UNIQUE-SUBVOL
2101 ZPHI-EVT-NO-UNIQUE-SUBVOL
An empty ZDLLrrr[a] subvolume to place public DLLs in could not be found.
ZPHI-TKN-EXT-NAME
is the fully qualified subvolume name that DSM/SCM uses to create a new target
subvolume (TSV) for public DLLs.
Cause. All 27 possible subvolumes already exist.
Effect. The Apply stops restartable.
Recovery. Remove or rename one or more of these subvolumes that are no longer
needed and restart the Apply. DSM/SCM no longer needs these subvolumes if no
ZPHI6030 file is present.
Tokens
ZPHI-TKN-EXT-FNAME <1> token-type ZSPI-TYP-STRING
Message Text
An empty <1>[A-Z] subvolume could not be found to place
public DLLs in. Remove or rename one or more of these
subvolumes and restart the Apply.