DSM/SCM Event Management Programming Manual

Event Messages
DSM/SCM Event Management Programming Manual529844-003
5-91
3006 ZPHI-EVT-NO-A1CNFG-FILE
3006 ZPHI-EVT-NO-A1CNFG-FILE
A distribution subvolume (DSV) does not contain an A1CINFO file.
ZPHI-TKN-INT-SVNM
is the name of the DSV where the error occurred.
Cause. The specified DSV did not contain an A1CINFO file, or the A1CINFO file has
an incorrect file code.
Effect. The activity finishes with warnings. The DSV is not processed as part of the
current input.
Recovery. A new DSV must be generated. Contact the product vendor. Because the
DSV was skipped, you must bring the DSV into DSM/SCM as a separate input. You
can then assign both inputs to the same input group through the Planner Interface. If
the input is an RVU or SPR, contact your service provider and provide all relevant
information:
Descriptions of the problem and accompanying symptoms
Details from any generated messages
Supporting documentation such as the $ZPHI EMS logs and trace files (if
requested by your HP support representative)
If your local operating procedures require contacting the Global Customer Support
Center (GCSC), supply your system number and the numbers and versions of all
related products as well.
Tokens
ZPHI-TKN-INT-SVNM <1> token-type ZSPI-TYP-SUBVOL
Message Text
The DSV <1> does not contain A1CINFO file. DSV skipped,
processing continues.