DSM/SCM Event Management Programming Manual

Event Messages
DSM/SCM Event Management Programming Manual529844-003
5-155
5022 ZPHI-EVT-HOST-RUNNING-PREAAX
5022 ZPHI-EVT-HOST-RUNNING-PREAAX
OVERRIDE parameters cannot be used if the host is not running on DSM/SCM version
T6031AAX or later.
Cause. The DSM/SCM product version of the host system is not T6031AAX or later.
Effect. The Apply stops restartable.
Recovery. Install the SPR T6031AAX or later on the host system.
5023 ZPHI-EVT-NO-OVERRIDE-OS-DIFF
You must specify OVERRIDE-SYSNN-DIFFERENT-OS parameters to ignore the
difference in fingerprints of a file created by a system generation program.
ZPHI-TKN-file-name
is the name of the file created by a system generation program.
ZPHI-TKN-SYS-NN-NBR
is the octal number of the currently executing SYSnn subvolume.
Cause. DSM/SCM detected that the new file created by a system generation program
is different from the one in the executing SYSnn subvolume. OVERRIDE parameters
were not specified to ignore the difference.
Tokens
None.
Message Text
OVERRIDE SYSnn not allowed because the host system is not
running DSM/SCM version T6031AAX or later
Tokens
ZPHI-TKN-file-name <1> token-type ZSPI-TYP-STRING
ZPHI-TKN-SYS-NN-NBR <2> token-type ZSPI-TYP-STRING
Message Text
DSM/SCM has detected that the new <1> file is different
(fingerprint) from the existing <1> file in SYSnn <2>. The
OVERRIDE-SYSNN param has been specified to allow the APPLY to
go to SYSnn <2> anyway. However, a change in this file
indicates that the OS has really changed. If you specify the
OVERRIDE-SYSNN-DIFFERENT-OS param and restart the request,
the existing file will not be replaced. Otherwise, either
coldload from a different SYSnn and RESTART the activity, or
CANCEL this activity and START a new APPLY specifying a
different target SYSnn.