DSM/SCM Event Management Programming Manual

Event Messages
DSM/SCM Event Management Programming Manual529844-003
5-191
5200 ZPHI-EVT-MISSING-PREV-SYSNN
5200 ZPHI-EVT-MISSING-PREV-SYSNN
DSM/SCM is deleting the previous configuration for a logical target from the target
system.
ZPHI-TKN-SUBVOL-NAME
is the name of the SYSnn subvolume related to the previous configuration.
ZPHI-TKN-TARGET-NAME
is the name of the logical target.
ZPHI-TKN-INT-VOL-NM
is the name of the system volume where the SYSnn subvolume was expected to
reside.
Cause. The physical system volume has been lost, or the specified logical target has
been deleted.
Effect. DSM/SCM deletes the previous configuration; therefore, no configuration
exists for you to backout to.
Recovery. Informational message only; no corrective action is needed.
Tokens
ZPHI-TKN-SUBVOL-NAME <5> token-type ZSPI-TYP-STRING
ZPHI-TKN-TARGET-NAME <3> token-type ZSPI-TYP-STRING
ZPHI-TKN-INT-VOL-NM <4> token-type ZSPI-TYP-DEVICE
Message Text
The SYSnn <1> for the previous configuration of target <2> is
missing from <3> and was not found anywhere else on the
system. The previous configuration is being deleted. Backout
will not be allowed. The DSM/SCM database will be updated
accordingly.