DSM/SCM Messages Manual

DSM/SCM EMS Messages
DSM/SCM Messages Manual529845-006
5-51
3007
3007
subvolume-name
is the name of the distribution subvolume (DSV) where the error occurred.
Cause. The A7CINFO file was removed from the DSV after the A0CINFO file was
generated.
Effect. The activity finishes with warnings. The DSV is not processed as part of the
current input.
Recovery. A new DSV must be generated. Contact the product vendor. Because the
DSV is skipped, you must bring the DSV into DSM/SCM as a separate input. You can
then assign both inputs to the same input group through the Planner Interface. If the
input is a release version update (RVU) or a software product revision (SPR), contact
your service provider and provide all relevant information:
Descriptions of the problem and accompanying symptoms
Details from any generated messages
Supporting documentation such as the $ZPHI EMS logs and trace files (if
requested by your service provider)
If your local operating procedures require contacting the Global Customer Support
Center (GCSC), supply your system number and the numbers and versions of all
related products as well.
The DSV
subvolume-name
has an entry in the A0CINFO file for
A7CINFO file, which is not present in the DSV. DSV skipped,
processing continues.