DSM/SCM Messages Manual
DSM/SCM EMS Messages
DSM/SCM Messages Manual—529845-006
5-54
3010
3010
subvolume-name
is the name of the distribution subvolume (DSV) where the error occurred.
filename
is the file name in the internal format of the DSV file that is not listed in the
A0CINFO file.
Cause. The A0CINFO file was missing an entry for a file in the DSV.
Effect. The activity finishes with warnings. The DSV is not processed as part of the
current input.
Recovery. The planner should contact the HP representative or the third-party
software representative concerning the missing entry to determine whether the file is
needed. If the DSV file is not needed, delete the file from the DSV. If the file is needed,
use CNFGINFO to create a new A0CINFO file for the DSV. If you need help
completing the correct CNFGINFO processing, contact the product vendor. Because
the DSV has been skipped, you must bring the DSV into DSM/SCM as a separate
input. You can then assign both inputs to the same input group through the Planner
Interface.
The DSV
subvolume-name
file
filename
has no entry in A0CINFO.
Planner must use CNFGINFO tool to update A0CINFO file for DSV
and bring it into DSM/SCM as a separate input, then assign
two inputs to the same Input Group. DSV skipped, processing
continued.