DSM/SCM Messages Manual
DSM/SCM EMS Messages
DSM/SCM Messages Manual—529845-006
5-64
3032
3032
Cause. A software input request was started while a Receive-All-Files software input 
request was already being processed.
Effect. DSM/SCM cannot process the input.
Recovery. Wait until the Receive-All-Files software input has completed, then restart 
the request.
3035
software-version
is the NonStop RVU ID.
Cause. The SUT contains software at an RVU earlier than C30.10 (C-series RVU) or 
D20 (D-series RVUs).
Effect. DSM/SCM cannot process the input.
Recovery. Ensure that you are using a SUT containing the correct RVU (C30.10/D20 
or later). 
3040
Cause. No products were processed for the software input activity. The error that 
caused this message appears in the message that precedes this one. 
Effect. The activity finishes with errors. No products were processed for the software 
input activity. 
Recovery. For the recovery procedure, consult the description in this manual of the 
preceding error message. Correct the error and retry the software input activity. 
A Receive-All-Files software input is in progress. No other 
software inputs can be received or cancelled until the 
Receive-All-Files software input completes. Restart this 
request after the Receive-All-Files software input completes.
Invalid SUT version 
software-version
. DSM/SCM can only accept 
SUTs for Release C30.10/D20 and later. Ensure you have SUT at 
correct release level.
No products were processed for this Software Input.










