3032
3032
Cause. A software input request was started while a Receive-All-Files software input
request was already being processed.
Effect. DSM/SCM cannot process the input.
Recovery. Wait until the Receive-All-Files software input has completed, then restart
the request.
3035
software-version
is the NonStop RVU ID.
Cause. The SUT contains software at an RVU earlier than C30.10 (C-series RVU) or
D20 (D-series RVUs).
Effect. DSM/SCM cannot process the input.
Recovery. Ensure that you are using a SUT containing the correct RVU (C30.10/D20
or later).
3040
Cause. No products were processed for the software input activity. The error that
caused this message appears in the message that precedes this one.
Effect. The activity finishes with errors. No products were processed for the software
input activity.
Recovery. For the recovery procedure, consult the description in this manual of the
preceding error message. Correct the error and retry the software input activity.
A Receive-All-Files software input is in progress. No other
software inputs can be received or cancelled until the
Receive-All-Files software input completes. Restart this
request after the Receive-All-Files software input completes.
Invalid SUT version
software-version
. DSM/SCM can only accept
SUTs for Release C30.10/D20 and later. Ensure you have SUT at
correct release level.
No products were processed for this Software Input.